Solve of low cost to elevate the energy efficiency in the sugar mills stations

Authors

  • Margarita Villamil Cid Empresa Azucarera “Héctor Rodríguez”. Sagua la Grande. Villa Clara. Cuba
  • Jesús E. Castellanos Estupiñán Universidad Central “Marta Abreu” de Las Villas. Santa Clara. Villa Clara. Cuba
  • Rubén Espinosa Pedraja Universidad Central “Marta Abreu” de Las Villas. Santa Clara. Villa Clara. Cuba

Keywords:

Diagnostic energy, energy Efficiency, Saving Potentials, electric consumptions

Abstract

The present work is carried out in the Sugar Company “Héctor Rodríguez”, with the objective of giving answer to deficiencies detected in a carried out energy diagnosis. They took technician-organizational measures, and they were carried out works guided to the saving and rational use of electric power through decrease of consumptions with solutions of low cost. The electric consumptions are compared before in the industry and after having applied the measures and the saving potentials are obtained that allow elevating the energy efficiency of the industry. It is demonstrated that without investing in teams and technologies, they can be carried out actions that alone they depend on technical knowledge, it disciplines, organization and control.

Downloads

Download data is not yet available.

Published

2008-01-01

How to Cite

Villamil Cid, M., Castellanos Estupiñán, J. E., & Espinosa Pedraja, R. (2008). Solve of low cost to elevate the energy efficiency in the sugar mills stations. Centro Azúcar Journal, 35(1). Retrieved from http://centroazucar.uclv.edu.cu/index.php/centro_azucar/article/view/485

Issue

Section

Original Articles

Most read articles by the same author(s)

<< < 1 2 

Similar Articles

You may also start an advanced similarity search for this article.