EVALUATION OF THE RESIZING OF THE WASTE TREATMENT PLANT OF THE TEXTILE COMPANY "DESEMBARCO DEL GRANMA", SANTA CLARA

Authors

  • Isabel Cabrera Estrada Departamento de Ingeniería Química. Facultad de Química y Farmacia, Universidad Central “Marta Abreu” de Las Villas, Carretera a Camajuaní, Km 5 ½. Santa Clara, Villa Clara, Cuba
  • Dora Mendoza Martínez Departamento de Ingeniería Química. Facultad de Química y Farmacia, Universidad Central “Marta Abreu” de Las Villas, Carretera a Camajuaní, Km 5 ½. Santa Clara, Villa Clara, Cuba
  • Ismaray Nuñez Departamento de Ingeniería Química. Facultad de Química y Farmacia, Universidad Central “Marta Abreu” de Las Villas, Carretera a Camajuaní, Km 5 ½. Santa Clara, Villa Clara, Cuba
  • Mercedes Arbona Cabrera Departamento de Ingeniería Química. Facultad de Química y Farmacia, Universidad Central “Marta Abreu” de Las Villas, Carretera a Camajuaní, Km 5 ½. Santa Clara, Villa Clara, Cuba
  • Ana M. Contreras Moya Departamento de Ingeniería Química. Facultad de Química y Farmacia, Universidad Central “Marta Abreu” de Las Villas, Carretera a Camajuaní, Km 5 ½. Santa Clara, Villa Clara, Cuba

Keywords:

wastewater, activated sludge, aeration tanks

Abstract

The increase of the sewage is a serious global problem. The objective of this work is to make an technical, economic and environmental evaluation of the resizing of the plant for the treatment of waste water from the textile company "Desembarco del Granma", in Santa Clara and to offer a proposal to improve the functioning of the same company, specifically with its process of biological treatment using activated sludge. As a preliminary step, using experimental techniques, the characteristics of the tributary and the effluent from the system were evaluated. COD values higher than 90 mg/L showed adverse implications for the body receiver and an apparent inability of the system to remove organic matter to the levels required. The recalculation of the parameters of design/operation of the plant for the current conditions of the tributary was made. It is obtained that these parameters are not within the recommended values and finally, it was proposed and evaluated the increased to 50 and 75 % of the volume of the aeration tank and the commissioning of two or three of the air vents. With the expansion of the plant's capacity will be achieve a treatment that allows the effluent meet established standards for dumping and therefore avoids damage to the environment and the payment of fines for these concepts. The economic indicators NPV, IRR and PBP calculated, demonstrate the acceptability of the investment required to implement the modifications. All this together proves that the project is deployable.

Downloads

Download data is not yet available.

Published

2015-12-01

How to Cite

Cabrera Estrada, I., Mendoza Martínez, D., Nuñez, I., Arbona Cabrera, M., & Contreras Moya, A. M. (2015). EVALUATION OF THE RESIZING OF THE WASTE TREATMENT PLANT OF THE TEXTILE COMPANY "DESEMBARCO DEL GRANMA", SANTA CLARA. Centro Azúcar Journal, 42(4). Retrieved from http://centroazucar.uclv.edu.cu/index.php/centro_azucar/article/view/237

Issue

Section

Original Articles

Most read articles by the same author(s)

1 2 > >>