PRESSURE LOSSES IN CEPIL FACTORY COMPRESSED AIR SYSTEM EVALUATION

Authors

  • Antonio Herrera Fernández UEB Cepil
  • Isnel Benítez Cortés Universidad de Camagüey “Ignacio Agramonte y Loynaz”
  • Luisa Matos Mosqueda Universidad de Camagüey “Ignacio Agramonte y Loynaz”
  • Lourdes Mariana Crespo Zafra Universidad de Camagüey “Ignacio Agramonte y Loynaz”
  • Alicia Rodríguez Gregorich Universidad de Camagüey “Ignacio Agramonte y Loynaz”

Keywords:

compressed air, plastic articles, plastic brushes, compressors, pressure losses.

Abstract

Nonconformity by defects in plastic items quality of the in Cepil Company may be caused by a malfunction of compression system and compressed air distribution. Losses in pipe sections, local resistances in distribution lines and pressure values reaching consumers were determined according to compressors output pressure and compared with the minimum pressure required for equipment properly work. The higher-pressure drops occurred in dental brushes production and the minimum compressor outlet must be between 5 and 5.78 atmospheres. Mathematical models describing this behavior are reported.

Downloads

Download data is not yet available.

Published

2019-12-01

How to Cite

Herrera Fernández, A., Benítez Cortés, I., Matos Mosqueda, . L., Crespo Zafra, L. M., & Rodríguez Gregorich, A. (2019). PRESSURE LOSSES IN CEPIL FACTORY COMPRESSED AIR SYSTEM EVALUATION. Centro Azúcar Journal, 46(4), 10. Retrieved from http://centroazucar.uclv.edu.cu/index.php/centro_azucar/article/view/15